4-20 mA Loop Calibrator PIE 334
With the PIECAL 334 you can check, calibrate and measure all your current signal instruments in a 4 to 20 milliamp DC loop. It can be used at any access point in your loop. Source & Read 0.00 to 24.00 mA, Simulate a 2 Wire Transmitter or use the PIECAL 334 to simultaneously power your 2 Wire Transmitter and measure its output.
Calibrate recorders, digital indicators, stroke valves or any instruments that get their input from a 4 to 20 mA loop. Easily set any value quickly to within 0.01 mA with the adjustable digitalpotentiometer “DIAL” or use preset 4.00 mA (0.0%) and 20.00 mA(100.0%) EZ-CHECK™ settings.
Just Like an Old Friend – A dependable milliamp loop calibrator
-
Calibrate Milliamp Instruments
Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA
Read 0.00 to 52.00 mA
Read -99.99 to 99.99 V
Simulate 2-Wire Transmitters; Power & Read 2-Wire Transmitters -
Calibrate with Confidence
Accurate to ±0.025% of Span at 4.00 & 20.00 EZ-CHECK outputs -
Use in the Plant, Field or Shop
Includes Rubber Boot and Attached Test Leads; Low profile switches resist accidental damage -
Simple Battery Changes
Separate compartment for no-tool battery changes with four inexpensive “AA” batteries -
Optional Accessories
AC Adaptor 120V (020-0101); 240V (020-0100); Deluxe Hands Free Carrying Case (020-0211); NiMh Batteries & Charger 100 to 240 VAC (North American Plug)/ (020-0103)
4-20 mA Loop Calibrator PIE 334
With the PIECAL 334 you can check, calibrate and measure all your current signal instruments in a 4 to 20 milliamp DC loop. It can be used at any access point in your loop. Source & Read 0.00 to 24.00 mA, Simulate a 2 Wire Transmitter or use the PIECAL 334 to simultaneously power your 2 Wire Transmitter and measure its output.
Calibrate recorders, digital indicators, stroke valves or any instruments that get their input from a 4 to 20 mA loop. Easily set any value quickly to within 0.01 mA with the adjustable digitalpotentiometer “DIAL” or use preset 4.00 mA (0.0%) and 20.00 mA(100.0%) EZ-CHECK™ settings.
Just Like an Old Friend – A dependable milliamp loop calibrator
-
Calibrate Milliamp Instruments
Source 0.00 to 24.00 mA & -25.0 to 125.0% of 4-20 mA
Read 0.00 to 52.00 mA
Read -99.99 to 99.99 V
Simulate 2-Wire Transmitters; Power & Read 2-Wire Transmitters -
Calibrate with Confidence
Accurate to ±0.025% of Span at 4.00 & 20.00 EZ-CHECK outputs -
Use in the Plant, Field or Shop
Includes Rubber Boot and Attached Test Leads; Low profile switches resist accidental damage -
Simple Battery Changes
Separate compartment for no-tool battery changes with four inexpensive “AA” batteries -
Optional Accessories
AC Adaptor 120V (020-0101); 240V (020-0100); Deluxe Hands Free Carrying Case (020-0211); NiMh Batteries & Charger 100 to 240 VAC (North American Plug)/ (020-0103)