Analog Earth Resistance Tester Hioki FT3151
Earthing or grounding of electrical equipment is essential to maintain safety, protecting lives, as well as prevent damage to equipment. The FT3151 Analog EarthTester uses the AC phase differential system to measure earthing resistance, which assures that accurate measurements are unaffected by earth voltage and auxiliary earthing resistance. New innovate cord winders make clean up a breeze.
Key Features :
- Three-electrode method, Two-electrode method (Simple Measurement)
- Wide measurement range for 0 to 1150 Ω, based on EN standard
- Switchable measurement frequency to reduce the effects of power supply harmonics
- Dramatically faster setup: Comes with improved grounding rods and cord winders
Weight | 0.130 kg |
---|---|
Dimensions | 13 × 7 × 3.2 cm |
Measurement system |
AC potentiometer method, Three-electrode method/ two-electrode method (switchable) |
Measurement range |
10 Ω (0 to 11.5 Ω) |
Functions |
Auxiliary earth resistance check S (P)/ H(C) |
Earth potential measurement |
0 to 30 V, Nominal Deviation: ±3.0 % f.s. |
Power supply |
LR6 (AA) Alkaline battery ×6, 1100 times operation (at 30 sec. measurement/ 30 sec. rest cycle) |
Dimensions |
164 mm (6.46 in)W × 119 mm (4.69 in)H × 88 mm (3.46 in)D |
Weight |
760 g (26.8 oz) |
Analog Earth Resistance Tester Hioki FT3151
Earthing or grounding of electrical equipment is essential to maintain safety, protecting lives, as well as prevent damage to equipment. The FT3151 Analog EarthTester uses the AC phase differential system to measure earthing resistance, which assures that accurate measurements are unaffected by earth voltage and auxiliary earthing resistance. New innovate cord winders make clean up a breeze.
Key Features :
- Three-electrode method, Two-electrode method (Simple Measurement)
- Wide measurement range for 0 to 1150 Ω, based on EN standard
- Switchable measurement frequency to reduce the effects of power supply harmonics
- Dramatically faster setup: Comes with improved grounding rods and cord winders
Weight | 0.130 kg |
---|---|
Dimensions | 13 × 7 × 3.2 cm |
Measurement system |
AC potentiometer method, Three-electrode method/ two-electrode method (switchable) |
Measurement range |
10 Ω (0 to 11.5 Ω) |
Functions |
Auxiliary earth resistance check S (P)/ H(C) |
Earth potential measurement |
0 to 30 V, Nominal Deviation: ±3.0 % f.s. |
Power supply |
LR6 (AA) Alkaline battery ×6, 1100 times operation (at 30 sec. measurement/ 30 sec. rest cycle) |
Dimensions |
164 mm (6.46 in)W × 119 mm (4.69 in)H × 88 mm (3.46 in)D |
Weight |
760 g (26.8 oz) |