Four Channel Thermometer - 800023
This unique portable thermometer displays data from 4 thermocouple probes simultaneously on a large back-lit LCD. Communicates with a computer via the bi-directional computer port and optional cable, and graphic software. Auto ranging with auto power off, min/max, hold, Δ (T1-T2) and relative functions. High full scale accuracy of ±0.5% rdg. + 1ºC / 2ºF. Easily calibrates to ice point, or any other standard. 0.1° resolution <200° & 1° >200°C. Wide measurement range of -328 to 2498°F (-200 to 1370°C). Comes ready to use with 2 beaded wire probes, instructions, and a 9V battery, in a protective, foam-lined case. Can also be used with optional AC Adapter (800003). N.I.S.T. traceable Certification Report available.
Range |
-200 to 200°C |
---|---|
Resolution |
±0.2% reading +1°C |
Accuracy |
-200 to 200ºF, 0.1ºF, else 1°F |
Number of Data Points |
16,000 |
Numerical Display |
4 digit LCD display per channel |
Sample Rate |
3 seconds per period |
Operating Temp/Hum. |
32 to 122°F, (-0 to 50°C); 0 to 80% RH |
Storage Temp/Hum. |
14 to 140°F, (-10 to 60°C); 0 to 80% RH |
Operating at Altitude |
Up to 2000 meters |
Input Protection at Thermocouple Input |
60V DC, or 24Vrms AC |
Battery Life |
Approx. 100 hours with an alkaline battery |
Dimensions |
7¼" × 2½" × 1¼" (184 × 64 × 32 mm) |
Weight |
8.4 oz (238 g) |
Four Channel Thermometer - 800023
This unique portable thermometer displays data from 4 thermocouple probes simultaneously on a large back-lit LCD. Communicates with a computer via the bi-directional computer port and optional cable, and graphic software. Auto ranging with auto power off, min/max, hold, Δ (T1-T2) and relative functions. High full scale accuracy of ±0.5% rdg. + 1ºC / 2ºF. Easily calibrates to ice point, or any other standard. 0.1° resolution <200° & 1° >200°C. Wide measurement range of -328 to 2498°F (-200 to 1370°C). Comes ready to use with 2 beaded wire probes, instructions, and a 9V battery, in a protective, foam-lined case. Can also be used with optional AC Adapter (800003). N.I.S.T. traceable Certification Report available.
Range |
-200 to 200°C |
---|---|
Resolution |
±0.2% reading +1°C |
Accuracy |
-200 to 200ºF, 0.1ºF, else 1°F |
Number of Data Points |
16,000 |
Numerical Display |
4 digit LCD display per channel |
Sample Rate |
3 seconds per period |
Operating Temp/Hum. |
32 to 122°F, (-0 to 50°C); 0 to 80% RH |
Storage Temp/Hum. |
14 to 140°F, (-10 to 60°C); 0 to 80% RH |
Operating at Altitude |
Up to 2000 meters |
Input Protection at Thermocouple Input |
60V DC, or 24Vrms AC |
Battery Life |
Approx. 100 hours with an alkaline battery |
Dimensions |
7¼" × 2½" × 1¼" (184 × 64 × 32 mm) |
Weight |
8.4 oz (238 g) |
YOU MAY ALSO LIKE