Skip to content
Experience our newly integrated website, designed to enhance your shopping journey with cutting-edge technology and user-friendly features.

Secondary Current Injection Test Set 50A-3PH MK2

SKU : TRT50A3P
MAKE : T&R TEST EQUIPMENT
MODEL : 50A-3PH MK2
WARRANTY : 1

Secondary Current Injection Test Set 50A-3PH MK2

The Secondary Current Injection Test Set 50A-3PH MK2 is a three phase injection system providing commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate.

The Secondary Current Injection Test Set 50A-3PH MK2 has a range of outputs allowing injection of currents as low as a few mA and as high as 50A. Voltages up to 18V are available on the main outputs. Three true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety.

The 50A-3PH is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. Auxiliary outputs and inputs are fuse protected. An auxiliary metering input is provided and can measure voltage, current, frequency, and the phase between any of the current outputs and an external voltage or current. The timing system is very flexible without compromising ease of use, allowing trip times, reset times and reclose times to be quickly measured to a high degree of accuracy. Two independently isolated contact inputs are provided, and the timing system may also be used as a stand-alone timer. 

The 50A-3ph can be used to test many types of single and three phase secondary protection including:

  •  Over and under current relays
  •  IDMT relays
  •  Auto-reclosers
  •  Time delay relays
  •  Earth fault relays
  •  Miniature circuit breakers
  •  Power relays
  •  Tripping relays
  •  Thermal relays

When used in conjunction with a DVS3 3 phase voltage source the 50A-3PH mk2 Secondary Current Injection may be used to test most types of protection requiring three voltages and three currents including: 

  •  Directional overcurrent relays
  •  Distance protection relays
  •  Phase angle relays
  •  Power transducers
  •  Power relays

Secondary Current Injection Test Set

Weight 10 kg
Dimensions 5 × 5 × 5 cm
Output Current

0-50A

Phase

Three phase output

Dimension

560 × 456 × 265 mm

Weight

24.9 kg

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Secondary Current Injection Test Set 50A-3PH MK2

The Secondary Current Injection Test Set 50A-3PH MK2 is a three phase injection system providing commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate.

The Secondary Current Injection Test Set 50A-3PH MK2 has a range of outputs allowing injection of currents as low as a few mA and as high as 50A. Voltages up to 18V are available on the main outputs. Three true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety.

The 50A-3PH is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. Auxiliary outputs and inputs are fuse protected. An auxiliary metering input is provided and can measure voltage, current, frequency, and the phase between any of the current outputs and an external voltage or current. The timing system is very flexible without compromising ease of use, allowing trip times, reset times and reclose times to be quickly measured to a high degree of accuracy. Two independently isolated contact inputs are provided, and the timing system may also be used as a stand-alone timer. 

The 50A-3ph can be used to test many types of single and three phase secondary protection including:

  •  Over and under current relays
  •  IDMT relays
  •  Auto-reclosers
  •  Time delay relays
  •  Earth fault relays
  •  Miniature circuit breakers
  •  Power relays
  •  Tripping relays
  •  Thermal relays

When used in conjunction with a DVS3 3 phase voltage source the 50A-3PH mk2 Secondary Current Injection may be used to test most types of protection requiring three voltages and three currents including: 

  •  Directional overcurrent relays
  •  Distance protection relays
  •  Phase angle relays
  •  Power transducers
  •  Power relays

Secondary Current Injection Test Set

Weight 10 kg
Dimensions 5 × 5 × 5 cm
Output Current

0-50A

Phase

Three phase output

Dimension

560 × 456 × 265 mm

Weight

24.9 kg

 

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare